Mindray Datascope Spectrum OR Patient Monitor
The Datascope Spectrum OR is an operating room patient monitor with additional measurements such as ECG, SpO2, NIBP, Spirometry, temperature, and BISx. It shares the same platform as the Passport 2 and can be equipped with either a Masimo or Nellcor SpO2. Its 12-inch high-contrast color display, quick-access menus, and one-touch functionality make it user-friendly. The Spectrum also offers 3-8 waveform configurations and BIS Consciousness monitoring, as well as Pre-anesthesia features such as 3 or 5 lead ECG and non-invasive blood pressure measurement using either a Nellcor or Masimo SpO2 system.
Specifications:
Dimensions
- Height with Module: 10.7 in (27.2 cm)
- Width With Module: 11.9 in (30.2 cm)
- Depth with module: 7.5 in (18.8 cm)
- Weight with modules: 1.75 lb ( 0.8kg)
- Weight with battery: 13.52 lb (6.1kg)
Display
- Size: 12.1-inch (30.7cm) Color Active Matrix TFT LCD
- Resolution: 800 x 600 pixels
- Waveforms: 3 to 8
ECG (3-lead and 5-lead)
- Leads: I, II, III, aVR, aVL, aVF, V
- Cable Detection: Autodetecting Datascope 3 or 5 wire
- Display Sensitivity: 0.25, 0.5, 1.0, 2.0, 3.0, 4.0, cm/mV ± 10%
- Frequency Response To Screen
- Extended Mode: 0.05 – 100 Hz, -3db
- Monitor Mode: 0.5 – 40 Hz, -3db
- ST Mode: 0.05 – 40 Hz, -3db
- ECG Sync Pulse for Cardioversion:
- Delay: ≤35 ms max between QRS Peak and the rising edge of Sync Pulse
- Amplitude: 2Vp minimum into a 5k ohm load
- Width: 2-7 ms
- Analog Output: (ECG)
- Delay: 25 ms max
- Sensitivity: 1 V/mV of input, ± 10%
- Defibrillator Overload Protection:
- Withstand 360 Joule discharge as per IEC 60601-2-27, 51.101.1
- Recovery Time: Time for recovery to within 1mV in < 8 seconds automatically. 3 seconds from 1Vpp at 60 Hz
Heart Rate Meter
- Range: 30 – 300 BPM Adult/Pediatric, 30 – 350 BPM
- Neonate
- Accuracy: ± 3 BPM or ± 3% at 30 – 250 BPM whichever is greater, ± 5% at 251 – 350 BPM
- Pacer Rejection: Rejects all pulses of amplitude ± 2.0 mV to ± 700 mV and duration 0.1 to 2 ms with no tail. AAMI EC-13-1992 4.1.4
- (3-Lead and 5-Lead) Rejects all pulses of amplitude ± 2.0 mV to 700 mV and duration 0.1 to 2ms with 100 ms time the constant tail of less than 2.0 mV, or 4 ms time the constant tail of < 2.0 mVper AAMI EC-13-1992 3.1.4.2 Tall T-Wave Rejection: Rejects all T-Waves of amplitude less than 120% of 1 mV, 100 ms QRS, T wave duration of 180 ms and Q-T interval of 350 ms per AAMI EC-13-1992 4.1.2.1 (c)
ST Analysis
- 3-lead or 5-lead Range: -9.9 mm to +9.9 mm
- Resolution: 0.1 mm
- Default ST Measuring Point: 80 ms after j point for HR <120 BPM, 60 ms after j point for HR >120 BPM
Arrhythmia Analysis
- 3-lead or 5-lead cables: Adult / Pediatric Only: Asystole, Irregular Heart Rate, Couplets, Bigeminy, Trigeminy, Ventricular Tachycardia, Ventricular Fibrillation, PVC ’s per minute, Runs,
- Ventricular Rhythm
Respiration (ECG)
- Range: 4 to 199 BPM
- Accuracy: ± 2% or 2 breaths per minute whichever is greater from 4 to 150 BPM, ± 4% from 151 to 199 BPM
- Lead: I or II
Non-Invasive Blood Pressure
- Technique: Oscillometric
- Systolic Range: Adult: 55 – 235 mmHg, Pediatric: 55 – 160 mmHg, Neonate: 45 – 120 mmHg
- Diastolic Range: Adult: 30 – 200 mmHg, Pediatric: 30 – 150 mmHg, Neonate: 20 – 100 mmHg
- Systolic Accuracy: Mean Error less than ± 5 mmHg, standard deviation less than ± 8 mmHg
- Diastolic Accuracy: Mean Error less than ± 5 mmHg, standard deviation less than ± 8 mmHg
- Pulse Rate Range: Adult/Pediatric: 35 to 245 BPM Neonate: 70 to 245 BPM
- Pulse Rate Accuracy: ±3 BPM or 3% whichever is greater
- Connector Type: Rectus
- Cuff Inflation: Volume of 500 ccs to 300 mmHg in ≤35 sec
Temperature
- Scale: Selectable C° or F°
- Range: 15° to 45°C / 59° to 113°F (T1 and T2) 0°C to 5.5°C / 0°F to 9.9°F (Delta T)
- Accuracy: ± 0.1°C (15°C to 45°C) exclusive of probe errors. ± 0.2°F (59°F to 113°F) exclusive of probe errors.
Pulse Oximetery
- Masimo SET SpO2 Accuracy Saturation with no motion conditions
- Adult/Pediatric: 70% to 100% ± 2 digits SpO2, 0 to 69% unspecified
- Neonate: 70% to 100% ± 3 digits SpO2, 0 to 69% unspecified
- Ear Sensor (Adult/Pediatric): 70% to 100% ± 4 digits SpO2, 0 to 69% unspecified
- Masimo SET SpO2 Accuracy Saturation during motion conditions
- Adult/Pediatric/Neonate: 70% to 100% ± 3 digits SpO2
- Response Time: 18 seconds to 95% of the final step of % SpO2 value from 60-95% at 75 BPM. Averaging set at 8 seconds.
- Pulse Rate Range Masimo with no motion conditions
- Adult/Pediatric/Neonate: 30-235 ±3 BPM, Ear Sensor (Adult/Pediatric) 30-235 ± 3 BPM
- Pulse Rate Range Masimo during motion conditions Adult/Pediatric/Neonate: 30-235 ±5 BPM
- Low Perfusion Performance
- Masimo: > 0.02% Pulse Amplitude and % Transmission > 5% / Saturation (%SpO2) ± 2 digits; Pulse ± 3 digits
- Nellcor OxiMax SpO2 Saturation Accuracy
- Adult/Pediatric/Neonate: 70% to 100% ± 3 digits
- Pulse Rate Range Nellcor: 20-249 ±3 BPM
IBP
- Range: Sys/Dia/Mean -30 to +300 mmHg
- Accuracy: ± 2 mmHg or 2% whichever is greater
- Scale: -10 to 10, 0-20, 0-40, 0-160, 0-225, 0-320, 60-140 mmHg
- Zero Range: ± 120 mmHg
- Excitation: 5V DC ± 2%
- Frequency Response: DC to 16 Hz ± 1Hz, -3db
Recorder
- Speed: 3.125, 6.25, 12.5, 25 mm, and 50 mm/sec
- Note: 3.125 speed is for CO2/Resp only.
Electrical Rating
- AC Voltage: 100 – 240 VAC ± 10%, 50/60 Hz ± 3 Hz
- Battery Type: Sealed Lead Acid
- Number of Batteries: 2
- Battery Voltage: 12 V
- Battery Capacity: 2.3 Ah
- Battery Run Time: 1 hour, 20 min from two fully charged, new batteries at 25° C with ECG, SpO2, and NIBP running at 15-minute intervals
- Recharge Time: 16 hrs max
OEM: Mindray
Model: Datascope Spectrum OR
Condition: Refurbished
Warranty: 365 days